Hydraulic breaker maintenance comes down to four routines: a walk-round before each shift, correct greasing and handling during work, a scheduled service for the gas charge and seals, and safe storage. Each routine protects different parts. This guide sets out the four, links every check to its detailed guide, and lists the model figures worth keeping with the machine.

Hydraulic breaker maintenance before each shift

Walk round the breaker with the attachment lowered and the engine off.

Check What to look for Detailed guide
Hoses and fittings Chafing, cracks, loose couplings, an oil film Hose guide
Oil leakage Fresh oil at the tool, the body joints or the ports Oil leak causes
Tool and retainer pins Cracks, a mushroomed or chipped tip, pins fully seated Pin guide
Tool bushing Visible play of the tool in the front head Bushing wear guide
Through bolts Movement or a gap at the body joints Through bolts guide
Grease Fresh grease at the tool, grease supply filled Grease guide

Anything found here is quicker to fix now than after a shift of blows. At the top rate a small breaker strikes up to 66,000 times an hour, so a loose bolt or a dry bushing does not stay small.

Hydraulic breaker maintenance during work

  • Grease in the right position. Press the tool into its working position before greasing, as the model manual describes. The grease guide explains why the position matters.
  • Stop when the material breaks. Blows with nothing under the tool, called blank firing, send the energy back into the breaker.
  • Do not pry. The tool is made to take blows along its axis. Levering with it bends the tool and loads the bushings.
  • Reposition instead of holding one spot. If the material does not break, move to an edge or a new point.
  • Watch the oil temperature. Oil that runs hotter with the breaker than with the bucket points to the flow or relief setting. Check both against the model window.

Operating technique is covered step by step in how to use a hydraulic breaker.

Scheduled hydraulic breaker maintenance

The interval comes from the model manual and the duty of the job. The service itself covers the same items on every breaker.

  • Nitrogen charge. Pressure in the back head, and in the accumulator where one is fitted, is checked by trained staff against the model chart. See the nitrogen pressure guide.
  • Seals. Seals are inspected, and replacements come as a kit for the exact model. See the seal kit guide.
  • Accumulator diaphragm. Checked with the gas system. See the accumulator and diaphragm guide.
  • Bushings. Wear is measured against the limit in the model manual. See the bushing wear guide.
  • Piston and valve. Surfaces are inspected whenever the breaker is opened. See the piston guide and the valve guide.
  • Through bolts. Inspected and tensioned to the model values. See the through bolts guide.

Figures to keep on the service card

Good hydraulic breaker maintenance starts with knowing what the carrier should deliver. Four figures per model tell a mechanic whether the excavator is feeding the breaker correctly. A reading outside the window is the first thing to correct, before any part is changed.

Model Chisel diameter Oil flow Working pressure Impact rate
LC-40 40 mm 15–30 L/min 90–120 bar 600–1,100 BPM
LC-45 45 mm 20–40 L/min 90–120 bar 600–1,100 BPM
LC-53 53 mm 20–50 L/min 90–130 bar 600–1,100 BPM
LC-68 68 mm 40–60 L/min 90–130 bar 500–990 BPM
LC-75 75 mm 50–90 L/min 120–150 bar 450–980 BPM
LC-100 100 mm 80–110 L/min 150–180 bar 350–700 BPM
LC-135 135 mm 100–150 L/min 160–180 bar 350–500 BPM
LC-140 140 mm 120–180 L/min 160–220 bar 350–450 BPM
LC-150 150 mm 130–190 L/min 170–190 bar 280–400 BPM
LC-155 155 mm 180–240 L/min 180–230 bar 200–300 BPM
LC-165 165 mm 190–260 L/min 200–240 bar 150–300 BPM
LC-175 175 mm 200–250 L/min 210–240 bar 120–200 BPM
LC-195 195 mm 250–320 L/min 260–300 bar 100–140 BPM
LC-200 200 mm 260–340 L/min 260–300 bar 100–140 BPM
LC-230 230 mm 330–430 L/min 260–300 bar 90–130 BPM

Figures from the LICH model specifications, read on 13 November 2026.

Storage

  • Clean the breaker and cap the hose ends so dirt stays out of the oil ports.
  • Grease the tool and the exposed part of the front head.
  • Rest the breaker in the position the manual approves, on a stand rated for its weight. The breaker stand guide covers selection, and the weight chart gives the weight of each model.
  • For long storage, follow the manual for the gas charge and the piston position.

Questions about hydraulic breaker maintenance

What hydraulic breaker maintenance is done every day?

The six checks in the first table: hoses, leaks, tool and pins, bushing play, through bolts and grease.

How often should a hydraulic breaker be greased?

Through the shift during heavy breaking. The exact interval and quantity come from the model manual, and fresh grease at the tool is the sign that it is reaching the bushings.

When should the nitrogen pressure be checked?

At each scheduled service, and whenever the blows weaken with correct oil flow and pressure.

Which spare parts support hydraulic breaker maintenance on site?

Start with a spare tool and a seal kit for the exact model. The hydraulic breaker parts page lists parts by model, and the first-order spare parts guide covers quantities.

Keep Comparing

Compare more breaker models and buyer guides related to this topic.

All guides
Get a Quote WhatsApp